9
Express® Lavatory System SS-Series
Installation Instructions SS-2N/IR/STD, SS-2N/IR/WH
Bradley Corporation • 215-1497 Rev. B; EN 03-808A 4/16/04
Installation Instructions
continued . . .
Step 4: Connecting supply and drain
1. Loosen but do not remove the two mounting screws holding the valve bracket to the frame. Slide
the valve bracket up until the larger cutout in the frame’s slot aligns with the screw head (see
Figure 5c). Then lift up to remove the valve bracket from the frame.
2. FOR HOT AND COLD SUPPLY: Using a thread sealer, thread the stop/check valve onto the hot
and cold wall stub-outs (see Figure 5a). Attach one end of the 1/2" flexible hose to the
Vernatherm™ valve (one hose on the hot side, the other hose on the cold side) (see Figure 5a).
Attach the other swivel end to the stop/check valve (located on the wall stub-out).
NOTE: The letter “H” on the Vernatherm™ Mixing Valve indicates hot water supply inlet.
FOR SINGLE TEMPERED SUPPLY: Using a thread sealer, thread the stop/check valve onto the
wall stub-out. Attach one end of the 1/2" flexible hose to the tempered line adapter and the other
end to the stop/check valve located on the wall stub-out (see Figure 5b).
3. Install the drain plug in the drain hole in the bowl (see Figure 5d).
4. Beneath the bowl, install the 1/8" rubber washer and the threaded tailpiece onto the drain plug.
5. Assemble the P-trap by connecting the 1-1/2" tubular pipe to the tailpiece and to the 1-1/2" drain
pipe stubbed out of the wall (see Figure 5e).
6. Install the strainer on the drain plug opening inside the bowl using the #8 screw.
Figure 5d
Figure 5a
Figure 5b
STRAINER
BOWL
1/8"
RUBBER
WASHER
DRAIN
PLUG
TAILPIECE
#8 SCREW